[Supported Models] RIGOL RSA800 Series Spectrum Analyzers
[Revision Date] August 28, 2026

[Current Release]
00.01.01.00.00
    - Added third-harmonic calibration functionality.
    - Added GMSK support to DMA, enabling GMSK signal demodulation using a Gaussian-filter-based MSK demodulation method; improved demodulation performance and stability for DMAFSK and 8PSK.
    - Optimized GPSA reference level, scale, and unit coupling behavior, and synchronized span display updates after center frequency (CF) modifications.
    - Updated the RTSA spurious avoidance scheme.
    - Fixed an issue where the RTSA density spectrum was not initialized after calibration.
    - Fixed EMI issues related to ESR command queries, reference level upper limits, scan time lower limits, and image rejection step path.
   - Fixed cursor anomalies after ADM peak-to-peak search operations and added support for SCPI frequency-setting parameters with engineering units.
   - Fixed issues with phase noise limit and trace-state restoration, as well as cursor anomalies during Preset operations.
   - Fixed spur issues in the 100 MHz intermediate-frequency (IF) path.
   - Added noise figure related resources and SCPI commands.
   - Optimized the segment table configuration strategy.

[Previous Releases]
00.01.00.00.21
    - Fixed incorrect coupling among External Gain, ATT, Reference Level, and Mixer Level settings.
    - Fixed Y-axis unit and scale errors after recalling a GPSA state.

00.01.00.00.20
    - Updated the RTSA spurious avoidance scheme.
    - Added a heartbeat mechanism for WebControl in WAN environments.
    - Optimized SweptSA AutoTune.
    - Added FFT analysis bandwidth options and expanded RBW configuration in 10% increments.
    - Modified the RTSA PA and ATT frequency-response calibration scheme to support calculations using both new and legacy calibration data.
    - Fixed the ADM span setting issue.
    - Fixed an issue where audio output stopped after changing RBW following successful FM demodulation.
    - Fixed a state-transition error after prolonged idle operation in Phase Noise mode.
    - Fixed a crash during Phase Noise trace processing.
    - Optimized the display of invalid cursor values.

00.01.00.00.19
    - Implemented several UI optimizations.
    - Added a Frequency Counter (Marker Counter) function in FFT mode.
    - Added immediate disk synchronization after file save operations.
    - Optimized the IP configuration experience and fixed related issues.
    - Fixed several audio demodulation issues.
    - Fixed EMI operation-timing exceptions after an AbortSequence operation.
    - Fixed a crash during HarmDist AutoFundamental search.
    - Upgraded the DMA equalizer algorithm to Version 3.0.
    - Fixed DMA/ADM TrigPort functionality issues.
    - Fixed amplitude-correction errors in the RTSA Density Ampt.
    - Fixed SingleSweep status exceptions in Repeat Average mode. 

00.01.00.00.18
    - Implemented UI optimizations.
    - Fixed inconsistencies in manual sweep-time behavior and optimized the sweep-time calculation strategy.
    - Updated the second-harmonic calibration function.
    - Fixed amplitude deviation with PA enabled in FFT mode.
    - Improved the GPSA AutoTune user experience.
    - Fixed several TG usability issues.
    - Fixed incorrect RTSA ATT/PA calibration-data handling.
    - Upgraded the VSA equalizer algorithm to Version 2.0.
    - Fixed several ADM issues.
    - Fixed ScreenList boundary-condition issues in multi-mode scenarios.

00.01.00.00.17
    - Improved stability when switching between SA and RTSA modes.
    - Set the detector type to Peak during GPSA AutoTune execution.
    - Fixed incorrect TG output amplitude.
    - Added an equalizer to DMA.
    - Implemented various DMA algorithm improvements. 
    - Fixed amplitude deviation when RTSA/ADM PA is on.
    - Implemented UI optimizations.

00.01.00.00.16
    - Implemented UI usability optimizations.
    - Optimized segmented spurious calibration.
    - Fixed multiple SCPI query issues.
    - Improved the GPSA AutoSpan function.
    - Improved limit-line interaction after trace dragging.
    - Implemented DMA algorithm optimizations.

00.01.00.00.15
    - Implemented UI optimizations.
    - Optimized span-switching strategies for RTSA, VSA, and ADM.
    - Fixed intermittent data issues in EMI single-point measurements.
    - Disabled the Marker Counter function in FFT mode.
    - Fixed an issue with the DANL function in Phase Noise mode.
    - Fixed excessive UNCAL warning indications.

00.01.00.00.14
    - Added FFT image-rejection functionality.
    - Added external-trigger support.
    - Fixed intermittent FPGA reset failures.

00.01.00.00.13
    - Optimized Phase Noise limit editing and fixed the issue where the limit function remained enabled after all limit lines were deleted.
    - Fixed ADM FM-demodulation cursor-frequency setting errors and FM/AM crosstalk issues.
    - Added ADM raw-data export and removed the audio-demodulation entry from TG mode.
    - Optimized the GPSA FFT sweep strategy and added Normal and Accurate sweep modes.
    - Expanded TG segmentation to 51 segments and fixed TG DAC command and related display issues.
    - Fixed LoRa measurement results, metrics, and decoded-information views showing no data.
    - Fixed RTSA density-spectrum flickering and incomplete display issues and optimized mask generation.
    - Fixed EMI final-measurement signal-data update logic.
    - Updated the DMA data-acquisition mode to return data through SCPI.
    - Fixed an issue where the Reference Marker could not be selected when traces were not updating.
    - Adjusted the maximum input attenuation to 30 dB.
    - Fixed and optimized UI display and interaction issues related to marker readouts, floating bars, status bars, and triggering.

00.01.00.00.12
    - Added UI support for Phase Noise, LoRa, Zigbee, and Bluetooth Low Energy (BLE) measurement modes.
    - Added SMB network-storage configuration support.
    - Added a standalone CW source option.
    - Renamed TG to Source and updated related menus accordingly.
    - Added per-band sweep-parameter configuration for Harmonic Distortion measurements.
    - Added FFT sweep switching in Phase Noise mode.
    - Optimized the 7-inch display user interface.
    - Optimized the GEL upgrade strategy to prevent overwriting user data and calibration data.
    - Optimized GPSA FFT point calculation, trace interpolation, and RTSA baseline processing.
    - Fixed failure to detect connection or disconnection of the 10 MHz external reference in FFT mode.
    - Fixed multiple display anomalies and system crashes when loading states or measurement data in GPSA, RTSA, and EMI modes.
    - Fixed incorrect Phase Noise decade-table data formatting.
    - Fixed Harmonic Distortion mode restart failures and the Marker Peak Search menu not opening correctly.

00.01.00.00.11
    - Added hot-loading support for 25 MHz IF-filter calibration coefficients.
    - Optimized dynamic FFT sweep-step calculation.
    - Fixed incorrect maximum ATT and Reference Level limits.
    - Fixed spurious traces appearing when switching from RTSA to GPSA.
    - Fixed the issue where the Reference Level could not be adjusted after switching from other modes to RTSA.
    - Fixed incorrect ADM span and ATT configurations for the current hardware platform.
    - Fixed standalone source-output failures and missing output in the 1.5 GHz to 8 GHz frequency range.
    - Fixed a crash in the GPSA → FFT → RTSA → Preset operation sequence.

00.01.00.00.10
    - Adjusted the ADC sample rate to 120 MHz and updated clocking, sweep segmentation, and IF-filter configurations accordingly.
    - Added firmware support for Phase Noise measurements.
    - Fixed RTSA density-spectrum display anomalies.
    - Fixed the issue where FFT mode did not sweep when RBW was below 3 Hz.

00.01.00.00.09
    - Added FFT sweep mode and fixed trace spurs and peak-amplitude readings that were approximately 10 dB too high during FFT sweeps.
    - Expanded the frequency-band table to improve frequency-switching smoothness.
    - Enabled image rejection by default.
    - Fixed inconsistencies between displayed and actual parameters after loading measurement data in GPSA and RTSA.
    - Fixed incorrect ACP adjacent-channel bandwidth multi-group commands.
    - Fixed amplitude anomalies in VSA and ADM modes.

00.01.00.00.08
    - Added 25 MHz IF-filter calibration and second-harmonic filter calibration.
    - Added CW amplitude control.
    - Fixed over-range protection and IF-overload protection issues.
    - Fixed the Preset function.
    - Fixed center-frequency and marker-position errors after Save/Recall operations.

00.01.00.00.07
    - Merged FFT-related code.
    - Corrected the instrument model name from RSA9xx to RSA8xx.
    - Fixed errors when saving signal lists and scan tables in EMI mode.
    - Fixed traces not refreshing after Recall operations.
    - Fixed incorrect RTSA minimum-span settings.
    - Fixed incorrect coupling between limit lines, Reference Level, and Reference Offset.
    - Fixed the issue where peak calculation was not performed when the GPSA Peak Table was opened.
    - Fixed multiple GPSA parameter-range issues and the ADM maximum-span issue.

00.01.00.00.06
    - Added V02 hardware support, including 40 MHz real-time analysis bandwidth, optimized LO paths, and updated TG mixing architecture.
    - Expanded the internal frequency-band table from 15 to 18 bands to improve frequency-switching smoothness.
    - Fixed limit-line amplitude display errors when the Y-axis was configured to use relative units.
    - Fixed incorrect Frequency Offset values after Save/Recall operations.
    - Fixed incorrect coupling between the RTSA Frequency Line and Center Frequency, and fixed the inability to set negative Center Frequencies.
    - Fixed the issue where attenuation mode did not switch automatically after ADM AutoTune execution.

00.01.00.00.05
    - Updated calibration code.
    - Updated the maximum TG output level to 0 dBm.
    - Fixed abnormal trace display during the first EMI Single Sweep.

00.01.00.00.04
    - Fixed intermittent crashes when switching modes after UI synchronization.
    - Fixed incorrect frequency-menu visibility logic across measurement modes.
    - Fixed blurred font rendering.
    - Fixed incorrect maximum TG CW Source frequency settings and output-state errors during mode switching.
    - Fixed incorrect RTSA default view, Marker status, and Y-axis scaling after Recall operations.

00.01.00.00.03
    - Optimized mode-switching performance.
    - Added automatic WebControl display scaling with browser-window resizing.
    - Fixed incorrect maximum ATT settings and corrected the limit to 30 dB.
    - Fixed intermittent crashes during GPSA AutoTune operation at high frequencies.
    - Fixed incorrect Y-axis scaling after state save and recall operations.
    - Fixed incorrect TG maximum frequency settings and corrected the limit to 14 GHz.
    - Fixed EMI limit-line amplitude update issues after changing Y-axis units.
    - Fixed several ACP UI issues.
    - Fixed incorrect maximum span settings in RTSA and ADM and corrected the limit to 25 MHz.

00.01.00.00.02
    - Added FM and AM audio-demodulation functions with UI menu support.
    - Optimized mode-switching performance.
    - Adjusted the maximum input-attenuation limit to 30 dB.

00.01.00.00.01
    - Added FPGA-based Frequency Counter and FM demodulation functionality and verified external-trigger and video-trigger features.
    - Added firmware support for FM and AM audio demodulation; UI menu support was scheduled for a later release.
    - Fixed FPGA firmware-version readback failures.
    - Fixed RTSA phase-lock loss issues and ATT/PA control failures.

00.01.00.00.00
    - Initial release with baseline functionality for GPSA, EMI, TG, RTSA, and VSA modes verified.